A global manufacturer with locations throughout asia, north and south america, australia and eur. Idec izumi microsmart plc programmable logic controllers distributors microsmart cpus are available in two types of modules, allinone and slim. Fc6a series pid module users manual idec corporation. All microsmart modules are manufactured unde r idec s rigorous quality control system, bu t users must add a backup or failsafe p. I suggest you replace it with the new microsmart pentra plc as soon as possible. The fc4ar081 is a microsmart digital output expansion module with 8port relay and removable screw terminal. The fc6a plus has a builtin 5mb of memory to store the users web page. Get the best deals on idec plc processors when you shop the largest online selection at. Do not connect the ground wire directly to the microsmart. Fc4a series micro programmable logic controller idec. Caution notices are used where inattention might cause personal injury or damage to equipment. Fc6a microsmart digital io cartridges users manual supplement.
Install the microsmart in environments described in this users manual. Read this users manual to make sure of correct operation before starting installation, wiring, operation, maintenance, and inspection of the microsmart. Microsmart users manual preface1 safety precautions read this users manual to make sure of correct operation before. The plus type has a dual rj45 ethernet port, embedded web server functions and the capability to expand up to 2060 io, while the allinone type has an embedded serial port and rj45 ethernet port capable of. Driver for data exchange with microsmart controllers from. Name language document description file size updated date remarks download. This manual describes procedures for using windldr ver. Custom web pages also can be constructed using the builtin web page editor in windldr software. The microsmart fc6a provides the power of a pac programmable automation controller in a lowcost controller with a small form factor, making it an ideal fit for demanding applications. The microsmart fc6a series is available in two types of cpus. Fc4a series micro programmable logic controller idec global. Install the microsmart in environments as described in the users manual. The microsmart is designed for installation in equipment. Creation of the optimum environment for humans and machines.
Programming microsmart is fast and straightforward. The allinone type has models with 10, 16 and 24 io points. This 4day class is to prepare system integrators to be confident in their ability to. Comparison between fc4a and fc5a cpu module functions. Fc4a series micro programmable logic controller users manual fc9yb8120a 2.
Make sure that the operating conditions are as desc ribed in the users manual. All microsmart modules are manufactured unde r idecs rigorous quality control system, bu t users must add a. All fc6a series microsmart modules are manufactured under idec s rigorous quality control system, but users must add a backup or failsafe. Do not install the microsmart outside of equipment. Microsmart 5m, rj45 connector, loose wire fc6akc1c for connecting hg2g3g to microsmart 5m, rj45 connector, dsub 9pin connector fc6akc2c io terminal cable 20pin shielded 0. Controller idec fc4ac10r2 user manual fc4a series microsmart micro programmable logic controller 525 pages. Microsmart pentra supplemental manual idec corporation. Microsmart users manual update introduction this manual includes additional descriptions of new modules and upgraded functionality in detail. Use idecs windldr software to configure, modify and monitor your microsmart programs with ease. Controller idec microsmart fc4a series replacement manual 46 pages controller idec fc4ac10r2 user manual. Fc4ar081 idec output module, microsmart fc4a series. Idec microsmart pentra programming manual pdf download. Name rs232c, mini din communication rs485, mini din adapter rs485.
Idec microsmart manual inputoutput computer data storage. Switches, estops, leds, safety products, terminal blocks, relays, plcs, explosionproof products answitches, estops, leds, safety products, terminal blocks, relays. Install the fc6a series microsmart according to the instructions described in the fc6a series microsmart allinone type users manual. Connect a protective ground to the cabinet containing. User manuals for idec corporation steven engineering. The microsmart is designed for installation in a cabinet. Idec smartrelay starter kit is an economical and ideal solution for. Fl1f smartrelay 6thgeneration smartrelay resources idec fl1f smartrelay brochure microsmart fc6a aio brochure smart relay micro site intelligently designed over the years the idec. The microsmart pentra has always meant speed, flexibility and power. Improper installation will result in falling, failure, o r malfunction of the microsmart. Manual system setup this section illustrates system setup congurations for using powerful communication functions of the microsmart. The idec registers are read and the return values cached in the rtu for access through an isagraf input board. Read the fc6a series microsmart lad programming manual to ensure correct operation before starting installation, wiring, operation, maintenance, and inspection of the fc6a series microsmart.
Microsmart plcs have always had the capability to operate high speed inputs and outputs, but microsmart pentra plcs can go even faster, up to 100 khz and so can your productivity. Install the microsmart according to the instructions described in this users manual. Program memory is 640 kb 80,000 steps with 1,024 timers and 512 counters, six highspeed at rates up to 100khz. The next generation idec microsmart fc6a plus plc stretches performance beyond. The new embedded ethernet microsmart pentra with web server functions boasts powerful features that no competitor in the micro plcs market can match. If you dont need ethernet, but still want a highperformance cpu, the microsmart pentra slim cpu is your best choice. Idecserialdriver setup supporteddevices micro1 micro3 microsmart opennet fa2j fa2 fa3scp11 fa3scp12 communicationprotocol idecasciiprotocol. About this manual this users manual describes brief information about the asinterface and the entire functions, installation, and programming of the microsmart asinterface interface module.
For output signals which may cause serious accidents, provide a monitor circuit outside the microsmart. This powerful and intuitive software makes it simple to get your system up and running. If the microsmart is used in places where the microsmart is subjected to hightemperature, highhumidity, condensation, corrosive gases, excessive vibrations, and. If you are uncertain about the specif ications, contact idec. Improper installation will result in falling, failure, or malfunction of the fc6a series microsmart. Stromquist training classes 5222019 fin stack training. Micro programmable logic controller, users manual read online or download pdf idec microsmart user manual manuals directory online owner manuals library search. The microsmart pentra plcs packs even more features into a small footprint to create an even more powerful controller with a response time up to 16 times faster than leading competitors plcs. Idec smartrelay series programmable logic controllers. If the microsmart is used in places where it is subjected to high. The plus type has a dual rj45 ethernet port, embedded web server functions and the capability to expand up to 2060 io, while the allinone type has an embedded serial port and rj45 ethernet port capable of expanding up to 520 io.
Preface1 fc6a series microsmart pid module users manual fc9yb1734 safety precautions read this manual to make sure of correct operation before starting installation, wiring, operation, maintenance, and inspection of the fc6a series microsmart pid modules. Idec microsmart manual free ebook download as pdf file. Additional memory can be utilized using optional sd memory card that supports up to 32gb. User communication and modem communication system the allinone 16 and 24io type microsmart. A builtin web page template is available if the user does not need to build his own. Microsmart series programmable logic controllers j12. Idec microsmart pentra plc programmable logic controller. Microsmart fc6a, a powerful plc with up to 520 digital io and 126 analogue io. Programmable logic controllers smartrelay 45 56 1224v dc, 24v acdc, 24v dc 100240v acdc 480 32k bytes 2k bytes yes yes. Catalogue cad manual downloads login or register to download cad data, manual, and software. Improper installation will result in falling, failure, or malfunction of the microsmart. The best way to communicate with this plc is using a program loader if you still have it. All functions are available on fc5ad12k1e and fc5ad12s1e with system program version. Microsmart fc5a users manual basic volume idec corporation.